by Breymesser, A.; Katrik, P.; Boeck, H. (Atominstitut der Oesterreichischen Universitaeten, Wien (Austria)); Sumah, P. (Ghana Atomic Energy Commission, Accra (Ghana))

An improved method for thermal power calibration of a low power TRIGA reactor is described using five electrical submersion heaters with a total output of about 20 kW. The temperature increase of the reactor pool water is monitored with six Pt-100 temperature sensors. The results are compared with the initial power calibration 32 years ago. (author)

Source/Report: Stritar, A.; Jencic, I. (Nuclear Society of Slovenia (Slovenia)) (eds.); European Nuclear Society (Switzerland); Ministry of Science and Technology of Slovenia, Ljubljana (Slovenia); Jozef Stefan Institute, Ljubljana (Slovenia); Nuclear Safety Administration of Slovenia, Ljubljana (Slovenia); 615 p; ISBN 961-90004-9-8; Worldcat; 1995; p. 44-47; 2. Regional Meeting on Nuclear Energy in Central Europe; Portoroz (Slovenia); 11-14 Sep 1995; INIS-SI–001; 4 figs.

Publ. Year: 1995